Unvented Hot Water Cylinder Service template
Annual unvented cylinder service: expansion vessel, pressure and temperature relief valves, discharge pipework and controls.
Opens in a free trial with this form ready to use.
Download printable PDF (72 KB)Building Regulations Approved Document G3
This template is provided as a starting point only. pro-Forms accepts no liability for the accuracy or suitability of its forms. Check every form with a suitably qualified person before using it in a live environment.
About this template
An annual service record for an unvented hot water cylinder. Record the cylinder details and the engineer's G3 qualification, then check the incoming mains pressure and flow, pressure reducing valve and strainer, expansion vessel charge, expansion relief valve, temperature and pressure relief valve, tundish and discharge pipework, thermostats and high-limit cut-out, immersion heater and leaks.
The engineer confirms whether the cylinder is safe to use, adds recommendations and gets the customer's signature.
What's on this form
Every field in the template, grouped as it appears on the phone. Required fields are marked *.
1. Details
- Customer name * Text
- Site name Text
- Site address Paragraph
- Job reference Text
- Date of visit * Date
- Time on site Time
- Time off site Time
- Cylinder make Text
- Cylinder model Text
- Cylinder serial number Text
- Cylinder ID / barcode Barcode scan
- Cylinder location Text
- G3 qualification card number Text
2. Checks
- Incoming mains pressure and flow * Pass / Fail / N/A Choice
- Pressure reducing valve and strainer * Pass / Fail / N/A Choice
- Expansion vessel charge checked * Pass / Fail / N/A Choice
- Expansion relief valve operated * Pass / Fail / N/A Choice
- Temperature / pressure relief valve operated * Pass / Fail / N/A Choice
- Tundish visible and discharge clear * Pass / Fail / N/A Choice
- Discharge pipework correctly routed * Pass / Fail / N/A Choice
- Thermostats and high-limit cut-out * Pass / Fail / N/A Choice
- Immersion heater * Pass / Fail / N/A Choice
- No leaks * Pass / Fail / N/A Choice
- Mains pressure (bar) Text
- Expansion vessel pressure (bar) Text
- Stored water temperature (°C) Text
3. Result
- Cylinder safe to use? * Yes / No Choice
- Recommendations Paragraph
- Additional comments Paragraph
- Engineer name * Text
- Engineer signature * Signature
- Date signed * Date
- Customer name (print) Text
- Customer signature Signature
Questions about this template
How often should an unvented cylinder be serviced?
Manufacturers recommend an annual service, and it is usually a condition of the warranty.
Who can work on an unvented cylinder?
Installation must be carried out by someone with an unvented hot water (G3) qualification, under Building Regulations Part G. Servicing should be done by a suitably qualified engineer too.
Why check the tundish?
The tundish shows if a relief valve is discharging. Water dripping through it means the expansion vessel or a valve needs attention.